Search results for "Coronary Plaque"
showing 3 items of 3 documents
Reproducible coronary plaque quantification by multislice computed tomography
2007
BACKGROUND: The aim of this study was to investigate reproducibility and accuracy of computer-assisted coronary plaque measurements by multislice computed tomography coronary angiography (QMSCT-CA). METHODS AND RESULTS: Forty-eight patients undergoing MSCT-CA and coronary arteriography for symptomatic coronary artery disease and quantitative intravascular ultrasound (IVUS, QCU) were examined. Two investigators performed the QMSCT-CA twice and a third investigator performed the QCU, all blinded for each other's results. There was no difference found for the matched region of interest (ROI) lengths (QCU 29.4 +/- 13 mm vs. QMSCT-CA 29.6 +/- 13 mm, P = 0.6; total length = 1,400 mm). The compari…
Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary…
2007
Attenuation variability ( measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/infinity) and a 1/50 solution of contrast material ( 400 mgI/ml iomeprol). Scan parameters were: slices/ collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques …
Discrimination of early/intermediate and advanced/complicated coronary plaque types by radiofrequency intravascular ultrasound analysis
2002
Radiofrequency intravascular ultrasound (IVUS-RF) analysis, as an extension of conventional IVUS imaging, may provide more accurate plaque discrimination. Thirty-two autopsy atherosclerotic coronary arteries were investigated. Corresponding sectors in different plaques were matched by histologic and RF analysis. Histologic analysis utilized the American Heart Association plaque classification. The backscattered ultrasound RF signal was analyzed by fast-Fourier transform, providing the underlying frequency components of its power spectrum. The normalized backscattered signal power (in decibels [dB]) for frequencies between 15.3 and 40.3 MHz was then measured for plaque discrimination. Advanc…